Production / Microwave detectorsLUCH-M
Microwave Bistatic Detector "LUCH-M"
"LUCH-MI" Microwave Bistatic Detector with RS-485 interface
Purpose
The purpose of local protective microwave detectors of "LUCH-M" is
to protect perimeter sectors of different sites and to generate alarms by
breaking output contacts of the individual point relay when an intruder crosses
a detection zone.
General Information
- The detector is a bistatic microwave detector consisting of a transmitter
and a receive.
- The principle of the detector operation is to generate an electromagnetic
field in the space between a transmitter and a receiver. The field forms a
volumetric detection zone in the form of a stretched ellipsoid of rotation and
registers the changes of this field when an intruder crosses a detection zone.
- The detector provides continuous round-the-clock operation and keeps its
specifications when the temperature is -40°Ñ...+50°Ñ and relative humidity is
up to 98 % at +35°Ñ temperature.
- The detector keeps operating and it is immune to:
- precipitations such as snow, fog and rain;
- solar radiation;
- wind at a speed of up to 30m/sec.;
- circulation of birds and small animals (a rat, a cat, etc.);
- the height of surface irregularities in a detection zone + 0,3m maximum;
- the height of snow blanket without additional adjustment up to 0,5 m;
- the height of grass up to 0,3m;
- EMI according to GOST R 50009-92.
Distinctive Features
- Signal processing is used in the detector. It allows:
- to enhance noise immunity, protect against adverse weather conditions
and circulation of small animals;
- to design "LUCH-MI" modification with RS-485 interface, which allows to
connect the detector to a computerized security panel over a 2-wire
communication line and to expand its functional capabilities (the detector
operation control from an acquisition system, ability to acquire information
about the detector status and etc.);
- to update software on the on-the-fly basis while expanding functional
capabilities.
- The detector is immune to strong electromagnetic fields (power lines up to
500 kW).
- The detector can detect a crawling intruder in case of special preparation
of a sterial zone and sensitivity adjustment.
- The detector can be adapted to the sector owing to the available
adjustment means.
- There is an expanded range of supply voltages in the detector within
6...35V.
- A built-in power unit with a high coefficient of efficiency has "fluent"
activation. It reduces the detector consumption in several times when power
supply is switched on.
- The detector power consumption is constant within the whole range of
supply voltages and it is 0,62 W. It allows to enlarge a number of kits per
one supply circuit or to use a cable with a less section.
- Microstrip manufacturing technique of SHF units.
- Simplicity and reliability of attachment points.
- It can be connected to different data acquisition systems.
- It is intended to replace the detector "PION". Thereto, additional
assembly works are not required because the detector plug-and-sockets are the
same.
- It is delivered with a custom-built power supply unit and all necessary
cables for connection.
Specifications
- The detection zone length is 10...300 m.
- Width of a detection zone is:
- 5 m if the maximum length of a sector is 300 m;
- 4 m if the maximum length of a sector is 200 m;
- 3 m if the maximum length of a sector is 100 m;
- 2 m if the maximum length of a sector is 50m.
- The height of a detection at the maximum length is 2 m minimum.
- The detector generates an alarm when:
- a person crosses a detection zone at a speed of 0,3…10m/sec.;
- there is remote control of operation;
- supply voltage is below normal;
- there is simultaneous failure of mains voltage and backup power supply;
- there is an attempt to mask a receiving unit of the detector;
- there is an attempt to demount the detector;
- the detector units are out of order;
- there is an attempt to tamper the detector units.
- Probability of detection is 0,98 minimum.
- Supply voltage is 6…35 V.
- Minimal alarm duration is 3 sec.
- Maximum time of availability for operation is 30 sec. after power supply
is ON.
- Maximum time of availability for operation is 0,5 sec. after an alarm is
generated.
- Maximum consumption current is 0,021 À at 35 V supply voltage.
- The individual point relay parameters:
- maximum switched current is 0,1 A;
- maximum switched current is 0,1 A.
- The protection rate of the enclosure is IP-55.
- Maximum dimensions (a mounting kit is not included):
- transmitter - 205 * 205 * 80 mm;
- receiver - 205 * 205 * 80 mm.
- Maximum weigth (a mounting kit is included) without a power unit - 2,0 kg.
Operating Characteristics
- Mounting: the detector is mounted on a post 70…200mm diameter with a steel
flexible buckle with subsequent rigid fixing of a bracket or on the wall.
- Wiring: connection to the units using braid connectors and their
connection to the junction box contacts or power unit contacts according to
the wiring layout.
- Alignment: positioning of the detector units on the angle and azimuth to
receive the maximum radiated signal on the connected voltmeter.
- Adjustment: operation thresholds are set at different tactics of detection
zone crossing according to the length of a protected sector and relief. The
built-in indicators carry out the control.
- Performance check – check passes or remote operation check.
Delivery Kit
Transmitter -1 item;
Receiver -1 item;
Mounting kit -1 kit;
Kit of tools and accessories- 1 kit;
Power supply unit -1 item;
Kit of braids -1 kit;
Technical specification and user manual- 1 item;
Certificate(copy)- 1 item.
.
|