Production / Microwave detectorsBARIER-300/500
Microwave Bistatic Detectors
“BARIER-300T/500T”-Extended Temperature Range.
Purpose
The purpose of local protective microwave detectors “BARIER-300/500”,
is to protect perimeter sectors of different sites.
General Information
The detector is a bistatic microwave detector consisting of a transmitter and a
receiver, which are connected by a synchronization cable.The principle of the
detector operation is to generate an electromagnetic field in the space between
a transmitter and a receiver. The field forms a volumetric detection zone in the
form of an oblong ellipsoid of rotation and registers the changes of this field
when an intruder crosses a detection zone.
Distinctive Features
- No “dead zones” on detection.
- Narrow detection zone.
- The detector is immune to the influence of strong electromagnetic fields (power
lines up to 500 kV).
- The detector can detect a crawling intruder in case of special preparation
of a sterial zone and sensitivity adjustment.
- Operation at a high level of snow.
- The detector can be adapted to the sector owing to the available
adjustment means.
- High interference immunity.
- Minimal seasonal work at a protected sector.
Specifications
- Detection zone length is 10...500 m.
- The width of a detection zone is the following:
- 3,5m, when the length of a sector is 500m;
- 2,7m when the length of a sector is 300m;
- 1,9m when the length of a sector is 150m.
- The minimum height of a detection zone is 1,9m at the maximum sector
length.
- The detector generates alarms when:
- an intruder crosses a detection zone at a speed of 0,3…10m/sec.;
- there is remote control of operation;
- supply voltage is below normal one;
- there is simultaneous failure of mains voltage and backup power supply;
- the detector units are tampered;
- there is an attempt to mask a receiving unit of the detector;
- there is an attempt to demount the detector;
- the detector units are out of order
- Probability of detection is 0,98 minimum.
- The detector supply voltage is 9…30 V.
- Maximum consumption current is 0,04 À.
- Maximum time of availability for operation is 30 sec. after power supply
is ON.
- Minimal duration of an alarm is 3 sec.
Operating Characteristics
- Mounting: the detector is mounted on a post 70…200 mm diameter with a
steel punched tape-tie with subsequent rigid fixing of a bracket.
- Wiring: connection of labelled wires of the detector unit braids to the
junction box contacts according to the wiring layout.
- Alignment: positioning of the detector units on the angle and azimuth to
receive the maximum radiated signal on the connected voltmeter.
- Adjustment: operation thresholds are set at different tactics of detection
zone crossing according to the length of a protected sector and relief. The
built-in indicators carry out the control.
- Operation check: check passes or remote operation check.
Delivery Kit
Transmitter - 1 item;
Receiver - 1 item;
Mounting kit - 1 kit;
Technical specification and user manual - 1 item;
Certificate(copy) - 1 item.
.
|